Country-flame INGLS 24-N Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Four Country-flame INGLS 24-N. Country Flame INGLS 24-N User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 34
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INGLENOOK FIREPLACE GAS LOG SET
MODEL INGLS 24-N OR INGLS 24-P
NATURAL GAS OR PROPANE CONVERSIOIN KIT
Country Flame Technologies
A Division of American Products, LLC
900 George Street
Marshfield, MO 65706
417-859-0990
417-859-0192
www.countryflame.com
USA & CANADA TEST: TESTED BY:
Harmonized ANSI Z21.60-2003 WARNOCK HERSEY
CGA 2.26-MO3 & CAN/CGA-21.7.M91
COUNTRY FLAME TECHNOLOGIES
INSTALLLATION, OPERATION, AND MAINTENANCE MANUAL
WARNING: If the directions contained in this manual are not followed
exactly, a fire or explosion may result causing property damage, personal injury
or loss of life.
IF YOU SMELL GAS
FOR YOUR SAFETY
Do not light any appliance.
Do not touch electrical switches; do not use the phone in your
building.
Immediately call the gas company from a neighbor’s phone.
Follow gas company instructions.
Call the Fire Department if Gas Company doesn’t answer.
FOR YOUR SAFETY
Do not store or use gasoline or any flammables (vapors or liquids) in the vicinity of
this or any other appliance.
Installation and repair must be performed by a qualified service person or gas supplier.
© 2004 COUNTRY FLAME
Vue de la page 0
1 2 3 4 5 6 ... 33 34

Résumé du contenu

Page 1 - COUNTRY FLAME TECHNOLOGIES

INGLENOOK FIREPLACE GAS LOG SET MODEL INGLS 24-N OR INGLS 24-P NATURAL GAS OR PROPANE CONVERSIOIN KIT Country Fl

Page 2 - TABLE OF CONTENTS

Version 1.0b 10 discrepancy or to obtain necessary parts to replace any missing or damaged components. TABLE 2 provides a gas log kit part’s list for

Page 3

Version 1.0b 11 INGLENOOK GAS LOG KIT SPECIFCATIONS TABLE 3 provides specifications for both Inglenook natural gas and propane gas fuel log kits. Th

Page 4 - INTRODUCTION

Version 1.0b 12 INSTALLATION, BURNERS STEP 1: Once TABLE 1 has been filled in, once all parts have been removed from the Inglenook Fireplace and prope

Page 5 - SAFETY INFORMATION

Version 1.0b 13 STEP 2: The ember tray and rear burner assembly are now ready for installation. This assembly includes steel tray framing, the rear

Page 6 - NEW INSTALLATION

Version 1.0b 14 STEP 3: The front burner assembly is now ready for installation. This assembly includes the front burner tray and adjustable shutter

Page 7 - INGLENOOK PARTS REMOVAL

Version 1.0b 15 STEP 4: In STEP 4 the log grate assembly is installed in the Inglenook. This assembly is to be set into the alignment slots provided

Page 8 - PRESSURE TESTING

Version 1.0b 16 INSTALLATION, EMBERS STEP 6: FIGURE 14 shows the embers installed on the front and rear burner. The embers add a “burning ash effect

Page 9 - INSTALLATION FACTOR B:

Version 1.0b 17 INSTALLATION, GAS LOGS STEP 7: STEP 7 begins the process of installing the six logs that make up the Inglenook log set. It is impera

Page 10

Version 1.0b 18 FIGURE 17: THIRD LOG INSTALLATION FIGURE 18: FOURTH LOG INSTALLATION

Page 11

Version 1.0b 19 FIGURE 19: FIFTH LOG INSTALLATION FIGURE 20: SIXTH LOG INSTALLATION

Page 12 - FIGURE 6: STEP 1 COMPLETE

Version 1.0b 2 TABLE OF CONTENTS INTRODUCTION ...

Page 13

Version 1.0b 20 FIGURE 21: COMPLETED GAS LOG INSTALLATION The Inglenook gas log system installation is now complete. The installer can proceed to

Page 14 - FIGURE 10: STEP 3 COMPLETE

Version 1.0b 21 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or ex

Page 15 - STEP 5:

Version 1.0b 22 MAINTENANCE INSTRUCTIONS The frequency of performing Inglenook fireplace maintenance depends on site-specific conditions and the freq

Page 16 - STEP 6:

Version 1.0b 23 CHECK VENT SYSTEM FREQUENCY: Once during annual inspection. See General Vent Inspection. PERFORMED BY: Qualified service techni

Page 17

Version 1.0b 24 GENERAL PERIODIC INSPECTIONS Check the venting system annually and make sure the system is clear of any debris. Check flame patterns

Page 18 - Version 1.0b

Version 1.0b 25 PROPANE FUEL CONVERSION INSTRUCTIONS The Inglenook gas log kit is shipped from the Country Flame factory set for 65,000 Btu/hr natura

Page 19

Version 1.0b 26 STEP 10 Remove the two burners. Mark each burner as to their location. Refer to FIGURE 4 and TABLE 3 for proper air shutter adjust

Page 20

Version 1.0b 27 STEP 14 Open the gas supply and perform gas leak test. One of the best methods used to check for gas leaks is soap bubbles. Soap b

Page 21

Version 1.0b 28 TROUBLESHOOTING INSTRUCTIONS PROBLEM POSSIBLE CAUSE SOLUTION Air in gas lines Refer to Item #1 of the Set-Up Guide. Defective spill

Page 22 - FIGURE 22: STANDING PILOT

Version 1.0b 29 TROUBLESHOOTING INSTRUCTIONS (cont’d) PROBLEM POSSIBLE CAUSE SOLUTION Gas pressure to appliance is low. Refer to Item #2 in the Set-

Page 23 - GENERAL INSPECTIONS

Version 1.0b 3 TABLE OF CONTENTS NOVA mV SET-UP GUIDE...

Page 24 - FIGURE 23: BURNER ASSEMBLY

Version 1.0b 30 TROUBLE-SHOOTING GUIDE The 820 Nova millivolt control valve is available in three different configurations. They are the (1) Millvol

Page 25

Version 1.0b 31 NOVA mV SET-UP GUIDE The following information is provided to assist in the set-up of the 820 NOVA mV control valve. A certified pro

Page 26 - FIGURE 27: PILOT VALVE

Version 1.0b 32 SAFETY LABEL FIGURE 29: CONTROL PANEL OVERLAY

Page 27 - 1/16" to 1/8"

Version 1.0b 33 REPLACEMENT PARTS – INGLS 24N or INGLS 24P When requesting service or replacement parts for your fireplace, please provide model numb

Page 28 - TROUBLESHOOTING INSTRUCTIONS

Version 1.0b 34 LIMITED 10 YEAR WARRANTY To establish warranty dates a completed warranty card must be received at Country Flame Technologies, 900 Geo

Page 29

Version 1.0b 4 INTRODUCTION THANK YOU and CONGRATULATIONS on the purchase of a new Inglenook gas log kit. The Inglenook fireplace is a solid fuel (w

Page 30 - TROUBLE-SHOOTING GUIDE

Version 1.0b 5 SAFETY INFORMATION - The Inglenook gas log kit is designed to be installed only in an Inglenook solid-fuel burning fireplace that ha

Page 31 - NOVA mV SET-UP GUIDE

Version 1.0b 6 INSTALLATION PREPARATION IMPORTANT NOTE: Read and comprehend all instructions in this manual before beginning installation. Failure t

Page 32 - SAFETY LABEL

Version 1.0b 7 INGLENOOK PARTS REMOVAL Once cleaning or installation of the Inglenook solid fuel fireplace is complete, it is time to remove some par

Page 33

Version 1.0b 8 INSTALLATION, GAS LINE Installation of the Inglenook fireplace and the Inglenook gas log kit must conform to National Standards, NFPA

Page 34 - LIMITED 10 YEAR WARRANTY

Version 1.0b 9 SIT 820 NOVA mV GAS CONTROL VALVE The SIT 820 NOVA mV gas control value is part of the drop in assembly provided with the Inglenook ga

Commentaires sur ces manuels

Pas de commentaire